| AC V | 4/40/400/600V (4 Range auto) |±1.3%rdg|±5dgt (4/40V) (50/60Hz)
 |±1.6%rdg|±5dgt (400/600V) (50/60Hz)
 | 
| DC V | 400m/4/40/400/600V (5 Range auto) |±0.8%rdg|±5dgt(400mV - 400V)
 |±1.0%rdg|±5dgt(600V)
 | 
| Ω | 400/4k/40k/400k/4M/40MΩ (6 Range auto) |±1.0%rdg|±5dgt (400Ω - 4MΩ)
 |±2.5%rdg|±5dgt (40MΩ)
 | 
| Diode check | Test voltage approx. 0.3 - 1.5V | 
| Continuity check | Buzzer sounds when resistance is 120Ω or less. | 
| Capacitance | 50n/500n/5µ/50µ/100µF (5 Range auto) |±3.5%rdg|±10dgt (50nF)
 |±3.5%rdg|±5dgt (500n - 50µF)
 |±4.5%rdg|±5dgt (100µF)
 | 
| Frequency | 5/50/500/5k/50k/200kHz |±0.1%rdg|±5dgt (Measurable input: 1.5Vrms or more)
 | 
| Duty | 0.1 - 99.9% |±2.5%rdg|±5dgt (Pulse width / Pulse cycle)
 | 
| Data hold | The measured value can be hold by pressing Data hold button | 
| Battery voltage warning | When the battery voltage drops to 2.4V|±0.2V or less | 
| Auto power-off | Built-in | 
| Applicable standards | IEC 61010-1: 2001 CAT III 600V IEC 61010-031
 IEC 61326-1
 | 
| Power source | Button type battery LR44 (SR44)1.5V × 2 | 
| Dimensions | 190(L) × 39(W) × 31(D)mm | 
| Weight | Approx. 100g (including batteries) | 
| Accessories | Carrying case, LR44 (1.5V) × 2, Instruction manual |