  1. Fluke 190-502 500 MHz ScopeMeter® Test Tool
special
special 2
Fluke 190-502 500 MHz ScopeMeter® Test Tool

Fluke 190-502 500 MHz ScopeMeter® Test Tool

0 reviews | Write a review

Brand: FLUKE

Product Code: Fluke 190-502

Availability: On Request

  • Description
  • Reviews (0)

Why choose the new 500 MHz two-channel ScopeMeter® test tool?

A faster sample rate and higher bandwidth means greater accuracy and clarity. The scope will capture and display unknown waveform shapes, amplitudes and any disturbances. In order to display at least the fifth harmonic component of a signal, a good rule of thumb is to select a scope with a bandwidth of at least five times the maximum clock rate of the device under test. The faster the sample interval, the more accurate and detailed the scope will display a signal edge (dV/dt) and peaks of any reflections or transients.

  • See More, Fix More with the Two-Channel CAT IV Rated Fluke ScopeMeter®

    The Fluke ScopeMeter® 190-502 combine the highest safety ratings and rugged portability with the high performance of a bench oscilloscope. Designed for plant maintenance engineers and technicians, these tough ScopeMeter® test tools go into harsh, dirty, and hazardous industrial conditions to test everything from micro-electronics to power electronics applications.

    The 190-502 ScopeMeter® is the one test tool you will reach for to tackle just about any troubleshooting task. They include a multimeter, TrendPlot™ and ScopeRecord™ roll paperless recorder modes and hands free operation with Connect-and-View™ triggering, and much more:

    • Two electrically isolated inputs
    • CAT III 1000 V / CAT IV 600 V safety rated
    • 500 MHz bandwidth model
    • 5 GS/s
    • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
    • Dedicated 5000 Count digital multimeter
    • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
    • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
    • TrendPlot, trend measurement readings for up to 22 days
    • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
    • IP-51 rated for dust and drip proof to withstand harsh environments
    • Isolated USB ports for memory devices and PC connectivity
    • Li-Ion battery for extended operating timespan
      • Up to 4 hours (BP290 included standard) or up to 8 hour with optional BP291
      • Charge spare battery using optional external battery charger EBC290
    • Easy-access battery door to make it easy to swap batteries
    • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock

     

    Gain Four Times the Diagnostic Power Plus CAT IV Safety Rating

    The Fluke ScopeMeter® 190-502 portable scope is double-insulated two-channel floating oscilloscopes safety rated for measurements in CAT III 1000V/CAT IV 600V environments.

    oscilloscopeThree-dimensional testing for industrial systems »

    Inspect input signals, output feedback loops or safety interlocks simultaneously to find a range of problems including:

    • Circuit voltage/current overloading
    • Signal timing measurements and synchronization issues
    • Attenuation/input impedance mismatch
    • Signal fluctuation/drift

     

    oscilloscope

    Three-phase testing for diagnosing VSD, power inverters, and converters »

    • Test for harmonics, transients and loads at the three-phase power input
    • Troubleshoot dc to ac converters for faulty IGBT gates or filter circuits
    • Test PWM output for reflections and transients or voltage unbalance

    Safely measure from mV to kV

    Standard probes that cover a wide application range from mV to kV prepare you for anything from micro-electronics to heavy duty medium voltage electrical applications. Independent isolated inputs eliminate the risk of accidental ground short circuits by allowing you to make measurements in mixed circuits with separate ground references.

    Take on the Harshest Conditions with the only IP-51-rated Scope on the Market

    Rugged and shock-proof, all ScopeMeter® portable oscilloscopes are built for harsh environments. Their sealed cases protect them from dust, water vapor, drips, humidity and airborne pollutants, ensuring reliable accurate performance every time you need them.

     

    Meter mode

    Built in multimeter to quickly and conveniently perform precise measurements

    Built-in digital multimeter 2 channel models with isolated dual input scope and dedicated digital multimeter. Conveniently switch from waveform analysis to precise multimeter measurements using the built in 5000 count digital multimeter. Measurement functions include Vdc, Vac, Vac+dc, resistance, continuity and diode test. Measure current and temperature using suitable shunt, probe or adapter with wide range of scaling factors.

     

    oscilloscope

    Work a Full Shift on a Single Charge

    New high-performance batteries take advantage of Li-ion technology to keep you going strong for up to four hours. And with the easy-access battery door you can make battery swaps fast.

     

     

    scopemeter usbCapture and Share Waveforms Easily with New USB connectivity

    Two USB ports, electrically isolated from measurement input circuits offer you easy USB connectivity to a PC or USB memory devices. Store unlimited waveform, screen captures or instrument steups to a USB memory device. Connect to a PC USB interface to transfer and archive critical measurement data using FlukeView software for windows.

     

     

    See a Stable Display Instantly with Connect-and-View&trade Triggering

    Connect-and-View™ automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable, and repeatable display of virtually any signal including motor drive and control signals. Expedites measuring several test-points in rapid succession.

     

     

    Record Up to 48 Hours of High-Resolution Waveforms with ScopeRecord™oscilloscope

    ScopeRecord memory stores up to 30,000 data points per channel, capturing intermittents and fast glitches. (Two sets of multiple-channel recordings can be stored for later analysis.)

    • Stores events like motion profiles, UPS, power supply, and motor start-ups
    • With the Stop-on-Trigger mode, the ScopeMeter® 190-502 automatically recognizes a power failure and stores the waveform data preceding it
    • With the waveform zoom (up to 100x) you can look at the smallest details, like individual power cycles

     

    Record up to 22 days with TrendPlot™ paperless recorder to find intermittent faultsoscilloscope

    Intermittent faults can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Line outages, sags, or starting and stopping a motor can also cause a machine to stop. The TrendPlot function in the Fluke ScopeMeter® test tool helps find those faults by:

    • Plotting minimum and maximum peak values and average over time up to 22 days
    • Plotting any combination of voltages, amps, temperature, frequency and phase for all four inputs, all with time and date stamp to pinpoint faults
  • Specifications
    Bandwidth500 MHz
    Number of channels500 MHz: 2 channels
    Real-time sample rate5 GS
    Inputs2 scope plus DMM input
    Independently floating isolated inputsUp to 1000 V CAT III/600 V CAT IV between inputs, references and ground
    Timebase range10 ns - 2 min/div
    Input sensitivity2 mV-100 V/div
    Trigger typesConnect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
    Trigger sourceAny scope input channel, or external via DMM input
    Glitch capture8 ns
    Scope measurementsCursor: 7
    Automatic: 30
    Maximum record lengthScopeRecord mode: 30,000 pts
    Scope mode: 10,000 pts per input
    PersistenceDigital persistence giving analog oscilloscope-like waveform decay
    Waveform compareWaveform reference with automatic Pass/Fail testing
    DMM Specification
    Meter inputs (also used as External Trigger Input for the Oscilloscope Mode)4 mm banana inputs, fully isolated from scope inputs and from scope ground
    Maximum resolution5000 counts
    MeasurementsVDC, VAC rms, VAC + DC rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature °C or °F (using optional converter)
    Memory 2 Channel
    Screen + Setup: 30
    Recording: 10
    Display153 mm full color LCD with fast update rate
    Environmental Specifications
    Operating temperature0°C to 40°C Including Batteries
    0°C to 50°C Excluding Batteries
    Storage temperature-20°C to +60°C
    Operating altitudeUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
    Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
    Safety Specifications
    Electrical safety1,000 V CAT III/600V CAT IV (EN61010-1)
    Mechanical and General Specifications
    Size

Write a review