Fluke 1550C 5 kV Insulation Tester
Fluke 1550C 5 kV Insulation Tester
Includes:
Test cables with alligator clips (red, black, green)
Infrared adapter with interface cable
AC power cord
Soft carrying case
English manual
User's manual on CD-ROM
Quick reference card
Software license agreement
Registration card
USB-IR cable installation guide
The Fluke 1550C insulation resistance tester offers digital insulation testing up to 5 kV, making them ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables.
Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1550C is the perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.
- Features include: - Test voltages to up 5 kV and save time by trending on the spot only with Fluke Connect™
- CAT III 1000 V, CAT IV 600 V safety rating
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
- Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2 TΩ
- Timer settings up to 99 minutes for timed tests
- 3-year warranty
 
- Electrical Specifications - The tester's accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ± .25% per °C, except on the 20% bands add ± 1% per °C. - Insulation Resistance Measurement - Test voltage (DC) - 250 V - Range - < 250 kΩ, 
 250 kΩ to 5 GΩ
 5 GΩ to 50 GΩ
 > 50 GΩ- Accuracy (± reading) - Unspecified 
 5%
 20%
 Unspecified- 500 V - Range - < 500 kΩ 
 500 kΩ to 10 GΩ
 10 GΩ to 100 GΩ
 > 100 GΩ- Accuracy (± reading) - Unspecified 
 5%
 20%
 Unspecified- 1000 V - Range - < 1 MΩ 
 1 MΩ to 20 GΩ
 20 GΩ to 200 GΩ
 > 200 GΩ- Accuracy (± reading) - Unspecified 
 5%
 20%
 Unspecified- 2500 V - Range - < 2.5 MΩ 
 2.5 MΩ to 50 GΩ
 50 GΩ to 500 GΩ
 > 500 GΩ- Accuracy (± reading) - Unspecified 
 5%
 20%
 Unspecified- 5000 V - Range - < 5 MΩ 
 5 MΩ to 100 GΩ
 100 GΩ to 1 TΩ
 > 1 TΩ- Accuracy (± reading) - Unspecified 
 5%
 20%
 Unspecified- Bar graph range - 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) - Insulation test voltage accuracy - -0%, +10% at 1 mA load current - Induced AC mains current rejection - 2 mA maximum - Charging rate for capacitive load - 5 seconds per μF - Discharge rate for capacitive load - 1.5 s/μF - Leakage current measurement - Range - 1 nA to 2 mA - Accuracy - ± (5% + 2 nA) - Capacitance measurement - Range - 0.01 μF to 15.00 μF - Accuracy - ± (15% rdg + 0.03 μF) - Timer - Range - 0 to 99 minutes - Resolution setting - 1 minute - Resolution indication - 1 second - Live circuit warning - Warning range - 30 V to 660 V AC/DC, 50/60 Hz - Voltage accuracy - ± (15% + 2 V) - Software specifications - FlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8. - General Specifications - Display - 75 x 105 mm - Power - 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 - Charger Input (AC) - 85 V to 250 V AC 50/60 Hz 20 VA - This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. - Dimensions - 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in) - Weight - 3.7 kg (8.2 lb) - Temperature (operating) - -20°C to 50°C (-4°F to 122°F) - Temperature (storage) - -20°C to 65°C (-4°F to 149°F) - Humidity - 80% to 31°C decreasing linearly to 50% at 50°C - Altitude - 2000 m - Enclosure sealing - IP40 - Input overload protection - 1000 V AC - Electromagnetic compatibility - EN 61326 - Safety compliance - IEC 61010-1: Overvoltage category II, Pollution Degree 2. 
 IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III