Fluke i3000s Flex-24 AC Current Clamp, 610 mm

Fluke i3000s Flex-24 AC Current Clamp, 610 mm

0 reviews | Write a review

Brand: FLUKE

Product Code: Fluke i3000s Flex-24

Availability: On Request

  • Description
  • Reviews (0)

The i3000s Flex is an ac current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

  • Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm (7 in.)
  • CAT III 600 V safety rating
  • Electrical Specifications
    Current ranges30 A
    300 A
    3000 A
    AC rms
    Output sensitivity (AC-coupled)100 mV
    10 mV
    1 mV per A
    Load impedance100 kΩ minimum
    Accuracyat +25°C: ±1% of range (45 Hz to 65 Hz)
    Linearity10% to 100% of range: ±0.2% of reading
    Noise8 mV AC rms (30 A)
    2 mV AC rms (300 A, 3000 A)
    Frequency range10 Hz to 50 kHz (-3 dB)
    Phase error< ±1° (45 Hz to 65 Hz)
    ±10° (at 20 kHz)
    Position Sensitivitywith cable > 25 mm from the coupling: ±2% of range
    External fieldwith cable > 200 mm from the head: ±1% of range
    Power supply2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator or dedicated external power supply
    Temperature coefficient±0.08% of reading per °C
    Working voltagesee Safety standards section: 600 V AC rms or DC
    General Specifications
    Head circumference610 mm (24 in)
    Head cable diameter14.3 mm (0.56 in)
    Head bend radius38.1 mm (1.5 in)
    Cable length (head to electronics)2 m (6.56 ft)
    Output connection0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter
    Operating temperature range-20°C to +90°C (-4°F to 190°F) (head)
    -20°C to +85°C (-4°F to 185°F) (electronics)
    Storage temperature range-40°C to +105°C (-40°F to 221°F) (head)
    -20°C to +85°C (-4°F to 185°F) (electronics)
    Operating humidity15% to 85% (non-condensing)
    Weight180 g (0.396 lb) (head)
    190 g (0.419 lb) (electronics)
    Safety standardsBS EN 61010-1: 2001
    BS EN 61010-2-032: 2002
    BS EN 61010-031: 2002
    600 Vrms, Category III, Pollution Degree 2
    Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz
    EMC standardsEN 61326: 1998 +A1, A2, & A3
    Maximum conductor size610 mm or 914 mm, depending on model