Fluke 772 Milliamp Clamp Meter
Need more hours in your day?
Save time by NOT breaking the loop on 4-20 mA signal measurements.
Are you spending time:
- Taking mA measurements by removing a wire and breaking the loop
- Calling the control room to isolate a loop
- Testing analog input/output on a console
- Troubleshooting devices with mA inputs and outputs
- Repairing intermittent or erratic 4-20 mA loops
- Going back to the shop to get extra tools
If you need more time in your busy day take a good look at the Fluke 772 mA Clamp Meters. It’s designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.
Here are some specific ways the Fluke 772 Clamp Meters will help you:
Milliamp Clamp Features
Measure mA signals for PLC and control system analog I/O without breaking the loop
- Measures low level dc current
- Correlate process indication with real physical value
Measure output signals from transmitters without breaking the loop
- Maintain and troubleshoot process and automation equipment without breaking the loop
- No disruption to the process
Detachable clamp with extension cable
- Measurements in tight locations
- Enables measurements in difficult situations
Measurement Spotlight
- Illuminates hard to see wires in dark enclosures
- Measurement process is easier and quicker
Measure up to 99.9 mA range non-contact
- Wide range of measurements
- Measures 10 to 50 mA signals in older control systems
Automatic power off
- After 15 minutes and 2 minute automatic off for backlight and spotlight
- Saves battery life
Want simultaneous mA source/measure? Consider the Fluke 773 Milliamp Clamp Meter.
- The 772 mA Clamp Meter features: - Best in class 0.2% accuracy
- 0.01 mA resolution and sensitivity
- Measure 4 to 20 mA signals without “breaking the loop”
- Measure mA signals for PLC and control system analog I/O
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Detachable clamp with extension cable for measurements in tight locations
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically change the 4 to 20 mA output for remote testing
- Power saving features, auto-off, backlight timeout extend battery life
- Hold function captures and displays changing measurements
- Measure 4 to 20 mA signals with in-circuit measurement
- Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
- Source 4 to 20 mA signals for testing control system I/O or I/Ps
- mA output linear ramp or 25% step output
- Automatically change the 4 to 20 mA output for remote testing
 
- Specifications - Diameter of measurable conductor - 0.177” or 4.5 mm max - Operating temperature - -10 to 50ºC - Storage temperature - -25 to 60ºC - Operating humidity - < 90% @ <30ºC, < 75% @ 30 to 55ºC - Operating altitude - 0 to 2000 m - IP rating - IP 40 - Size - 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) - Weight - 410 g, (14.4 oz) - Vibration - Random 2 g, 5 to 500 Hz - Shock - 1 meter drop test (except the jaw) - EMI/RFI - Meets EN61326-1 - For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. - Temperature coefficient - 0.01% ºC 
 (< 18ºC or > 28ºC)- Power, battery life - (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms - Warranty - Three years for electronics 
 One year for cable and clamp assembly- Functional Specifications - mA measurement 
 (measured by clamp)- Resolution / range - 0 to 20.99 mA - Accuracy - 0.2% + 2 counts - Resolution / range - 21.0mA to 100.0 mA - Accuracy - 1% + 5 counts - mA measurement (measured in series with test jacks) - Resolution / range - 0 to 24.00 mA - Accuracy - 0.2% + 2 counts - mA source (maximum mA drive: 24 mA into 1,000 ohms) - Resolution / range - 0 to 24.00 mA - Accuracy - 0.2% + 2 counts - mA simulate (maximum voltage 50 V dc) - Resolution / range - 0 to 24.00 mA - Accuracy - 0.2% + 2 counts 