Fluke 714B Thermocouple Calibrator
For the temperature calibration professional that wants a highly accurate, easy-to-use, single function thermocouple temperature calibrator the Fluke 714B is the ideal test tool.
- The 714B can measure and simulate (17) different thermocouple types and millivolts
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Hanging tool designed in and included with every unit
- Configurable 0% and 100% source settings for quick 25% linearity checks
- Linear ramp and 25% step auto ramp based on 0% and 100% settings
- Dual inputs and backlit display for easy interpretation of measurements
- Power down settings remembered at power up for easy restart of tests
- 1-year and 2-year specifications and traceable certification of calibration
 
- General Specifications - Maximum voltage applied between any terminal and earth ground or between any two terminals - 30 V - Operating temperature - -10°C to 50°C - Storage temperature - -30°C to 60°C - Operating altitude - 2,000 m - Storage altitude - 12,000 m - Relative humidity (% RH operating without condensation) - Non condensing 
 90% (10°C to 30°C)
 75% (30°C to 40°C)
 45% (40°C to 50°C)
 (Without condensation)- Vibration requirements - MIL-T-28800E, Class 2 - Drop text requirements - 1 m - IP Rating - IEC 60529: IP52 - Electromagnetic environment - IEC 61326-1, Portable - Safety - IEC 61010-1, Max 30 V to earth, Pollution Degree 2 - Power supply - 4 AA NEDA 1.5A IEC LR6 batteries - Size (H x W x L) - 52.5 x 84 x 188.5 mm - Weight - 515 g - DC mA Measurement - Resolution - Range - Accuracy (% of reading + counts) - 0-24 mA - 0.001 mA - 0.010% + 2 μA - Temperature coefficient - ±(0.002% of reading + 0.002% of range) /°C (< 18°C or > 28°C) - Millivolt Measurement and Source - Resolution - Range - Accuracy (% of reading +counts) - -10 mV to 75 mV - 0.01 mV - 0.015% + 10 μA - Temperature coefficient - ±(0.002% of reading + 0.002% of range) /°C (< 18°C or > 28°C) - Thermocouple Input and Output - TC Type - Range (°C) - Measure (°C) - Source (°C) - 1 year - 2 year - 1 year - 2 year - E - -250 to 200°C - 1.3 - 2.0 - 0.6 - 0.9 - -200 to -100°C - 0.5 - 0.8 - 0.3 - 0.4 - -100 to 600°C - 0.3 - 0.4 - 0.3 - 0.4 - 600 to 1000°C - 0.4 - 0.6 - 0.2 - 0.3 - N - -200 to -100°C - 1.0 - 1.5 - 0.6 - 0.9 - -100 to 900°C - 0.5 - 0.8 - 0.5 - 0.8 - 900 to 1300°C - 0.6 - 0.9 - 0.3 - 0.4 - J - -210 to -100°C - 0.6 - 0.9 - 0.3 - 0.4 - -100 to 800°C - 0.3 - 0.4 - 0.2 - 0.3 - 800 to 1200°C - 0.5 - 0.8 - 0.3 - 0.3 - K - -200 to -100°C - 0.7 - 1.0 - 0.4 - 0.6 - -100 to 400°C - 0.3 - 0.4 - 0.3 - 0.4 - 400 to 1200°C - 0.5 - 0.8 - 0.3 - 0.4 - 1200 to 1372°C - 0.7 - 1.0 - 0.3 - 0.4 - T - -250 to -200°C - 1.7 - 2.5 - 0.9 - 1.4 - -200 to 0°C - 0.6 - 0.9 - 0.4 - 0.6 - 0 to 400°C - 0.3 - 0.4 - 0.3 - 0.4 - B 
 