  1. Electrical Measurements
  2. Fluke 1621 GEO Earth Ground Tester
special
special 2
Fluke 1621 GEO Earth Ground Tester

Fluke 1621 GEO Earth Ground Tester

0 reviews | Write a review

Brand: FLUKE

Product Code: Fluke 1621

Mejdaf part number 84-083

Availability: On Request

  • Description
  • Reviews (0)

The Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.

    • Easily capture values with single-button operation
    • 3-pole Fall-of-Potential earth testing for basic measurements
    • 2-pole resistance measurements for added versatility
    • Ensure accurate measurements with automatic ‘noise’ voltage detection
    • Hazardous voltage warning offers increased user protection
    • Clearly read and record data with a large, backlit display
    • Rugged holster and design for tough work environments
    • Portable size allows for easy transportation
    • Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting
    • 600 V Cat II
  • General Specifications
    Measuring functions3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage
    Intrinsic errorRefers to the reference temperature range and is guaranteed for one year
    Measuring rate2 measurements/second
    Battery1One 9 volt alkaline (LR61)
    Battery conditionLO-BAT is displayed if voltage drops below 6.5 V
    VoltagesBetween jacks H/C2 and E/C1250 Veff maximum (effective voltage)
    Between jacks S/P2 and E/C1250 Veff maximum
    Climatic classVDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87)
    Temperature performance2Working-10°C to +50°C (+14°F to +122°F)
    Operating0°C to +35°C (+32°F to +95°F)
    Storage-20°C to +60°C (+68°F to +140°F)
    Reference+23°C ±2°C (+73°F ±4°F)
    Temperature coefficient±0.1% of range per degree Kelvin
    SafetyIEC/EN 61010-1, 600 V CAT II, pollution degree 2
    Dimensions113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster
    Weight850 g (1.9 lb), including standard accessories, volume approximately 600 cm3
    Electrical Specifications
    Maximum deviationsE1Influence factorPosition
    E1Deviation influence0%
    E2Influence factorSupply voltage
    E2Deviation influence0%
    E3Influence factorTemperature E3
    E3Deviation influence2.3%
    E4Influence factorSerial interference voltage (20 V)
    E4Deviation influence0.6%
    E5Influence factorProbe- and auxiliary probe resistance
    E5Deviation influence10%
    Test voltage3.7 kV
    Protection typeIP 40; IEC/EN 60529
    Electromagnetic compatibilityEmissionIEC/EN 61326 Class B
    ImmunityIEC/EN 61326 Annex C
    RE Resistance measurementMeasuring methodCurrent-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557–5
    Open circuit voltage23 to 24 V AC
    Short circuit current> 50 mA AC
    Measuring frequency128 Hz
    Maximum permissible overload250 Veff
    Measuring time8 seconds (average from when START is pressed)
    Limit inputTester retains set value even if instrument is turned off (assuming battery power supply is sufficient)
    Automatic changeover of resolutionRH< 7 kΩ
    Resolution0.01 Ω
    RH< 50 kΩ
    Resolution0.1 Ω
    RH> 50 kΩ
    Resolution1 Ω
    Interference voltage display DC + ACVmax30 Veff
    Common mode rejection> 80 dB at 50 Hz and 60 Hz
    Ri680 kΩ
    Measuring uncertainty< 10% for pure AC and DC signals
    Measuring Range
    0.15 Ω to 20 ΩResolution0.01 Ω
    Display range0 to 19.99 Ω
    200 ΩResolution0.1 Ω
    Display range20 to 199.9 Ω
    2 kΩResolution1 Ω
    Display range200 to 1999 Ω
    Intrinsic Uncertainty±(6% of measured value + 5D)
    Operating uncertainty IEC 615573±(18% of measured value + 5D)