  1. Test & Measurement
  2. Electrical Measurements
  3. Fluke 1587 Insulation Multimeter
special
special 2
Fluke 1587 Insulation Multimeter

Fluke 1587 Insulation Multimeter

0 reviews | Write a review

Brand: FLUKE

Product Code: Fluke 1587

Mejdaf part number 83-464

Availability: On Request

  • Description
  • Reviews (0)

The Fluke 1587 Insulation Multimeters combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.

Whether you work on motors, generators, cables, or switch gear, the Fluke 1587 Insulation Multimeters are ideally suited to help you with your tasks and at a cost that is far less than buying the two products.

    • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
    • Insulation test: 0.01 MΩ to 2.0 GΩ
    • Auto discharge of capacitive voltage
    • Insulation test smoothing reading
    • Frequency
    • Capacitance
    • Diode test
    • Temperature
    • Min/Max
    • Low pass filter (for work on VSD's)
    • AC/DC Voltage
    • DC millivolts
    • AC/DC milliamps
    • Resistance (0.1 Ω to 50 MΩ)
    • Continuity
    • Three-year warranty
    • Remote probe, test leads, alligator clips
    • K-type thermocouple
    • Rugged, utility hard case
    • Auto power off to save battery power
    • True RMS
    • Large display with backlight
    • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
    • CAT III 1000V, CAT IV 600V measurement category
    • Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work
  • Specifications
    Voltage DCMaximum voltage1000 V
    Accuracy±(0.09% + 2)
    Maximum resolution0.001 V
    Voltage ACMaximum voltage1000 V
    Accuracy±(2% + 3)
    AC bandwidth5 kHz1
    1. with low pass filter; 3 db @ 800 Hz
    Maximum resolution0.1 mV
    Current DCMaximum amps400 mA
    Amps accuracy±(0.2% + 2)
    Maximum resolution0.01 mA
    Current ACMaximum amps400 mA
    Amps accuracy±(1.5% + 2)2
    2. 1 kHz bandwidth
    Maximum resolution0.01 mA
    ResistanceMaximum resistance50 MΩ
    Accuracy±(0.9% + 2)
    Maximum resolution0.1 Ω
    CapacitanceMaximum capacitance9,999 µF
    Accuracy±(1.2% + 2)
    Maximum resolution1 nF
    FrequencyMaximum frequency100 kHz
    Accuracy±(0.1% + 1)
    Maximum resolution0.01 Hz
    Temperature Measurement-40.0°C to 537°C
    -40.0°F to 998°F excluding probe
    Diode testRange/Resolution6 V / 1 mV
    Accuracy±(2% + 1)
    Insulation Test
    Minimum test current @ 1kΩ/V1 mA
    Test Voltages50, 100, 250, 500, 1000 V
    Maximum resistance per test voltage50 V 
    100 V 
    250 V 
    500 V 
    1000 V2 GΩ
    Maximum resolution per test voltage50 V0.01 MΩ
    100 V0.01 MΩ
    250 V0.1 MΩ
    500 V0.1 MΩ
    1000 V0.1 MΩ
    Accuracy per test voltage50 V±(3% + 5)
    100 V±(3% + 5)
    250 V±(1.5% + 5)
    500 V±(1.5% + 5)
    1000 V±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600 MΩ
    Environmental Specifications
    Operating temperature–20°C to +55°C
    Storage temperature-40°C to +60°C
    Humidity (without condensation)0% - 95% (10°C – 30°C)
    0% - 75% (30°C – 40°C)
    0% - 40% (40°C – 55°C)
    Operating altitude2000 m
    Safety Specifications
    Overvoltage categoryComplies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
    Agency approvals2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
    Mechanical and General Specifications
    Size203 x 100 x 50 mm (with holster)
    Weight624 g
    Warranty3 years
    Battery life alkalineMeter use1000 hours
    Insulation test u6seMeter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
    IP ratingIP40
    1577/1587 Data Sheet

Write a review

Note: HTML is not translated!
    Bad           Good
Related Products (4)
Fluke C25 Large Soft Case for DMMs Quick View

Fluke C25 Large Soft Case for DMMs

Give your Fluke tools the protection they deserve. You bought the best, why not protect them with Fl.....
Add to Wish List
Compare this Product
Fluke TPAK ToolPakTM Magnetic Meter Hanger Quick View

Fluke TPAK ToolPakTM Magnetic Meter Hanger

The Fluke TPAK ToolPak™ Magnetic Meter Hanger allows you to hang your meter on nails, hooks, and pip.....
Add to Wish List
Compare this Product
TL1550B TEST LEAD SET WITH ALLIGATOR CLIPS, RED/BLK/GRN Quick View

TL1550B TEST LEAD SET WITH ALLIGATOR CLIPS, RED/BLK/GRN

TL1550B Test Leads with Alligator Clips (Red, Black, Green)·      &nbs.....
Add to Wish List
Compare this Product
Hard Case FLUKE-2437514 - Model : C101 Quick View

Hard Case FLUKE-2437514 - Model : C101

Fluke C101 Hard CaseKey featuresHeavy-duty, portable hard-shell tool caseO-ring sealed for waterproo.....
Add to Wish List
Compare this Product