  1. Calibrators
  2. Electrical
  3. 5080/CAL 5080/CAL calibration software
special
special 2
5080/CAL 5080/CAL calibration software

5080/CAL 5080/CAL calibration software

0 reviews | Write a review

Brand: Fluke Calibration

Product Code: 5080/CAL

Availability: On Request

  • Description
  • Reviews (0)

Accurate, reliable analog meter calibration

The 5080A Multi-Product Calibrator calibrates your analog workload accurately and reliably, thanks to its high voltage and current compliance. With maximum burden up to 800 mA for ac/dc voltage, and voltage up to 50 V for ac/dc current, 5080A calibrators can drive a wide range of analog meters.

Options and accessories expand workload coverage

Options and accessories enable you to use the 5080A Multi-Product Calibrator to calibrate an even broader workload, including:

  • Clamp meters. The 9100-200 10/50 turn coil and 5500A/COIL 50-turn current coil enables the 5080A to calibrate most popular clamp meters at currents up to 1000 A rms amps.
  • Oscilloscopes. Oscilloscope calibration to 200 MHz quickly, easily, and cost effectively. Verify dynamic response, bandwidth, timing, multiple triggering functions, and input resistance.
  • Megohm meters. This option sources high ohms, high voltage resistors up to 18 G ohms. It also measures high voltage outputs.

Protective circuits prevent damage

Mains voltage inadvertently applied to a calibrator’s output terminals can cause extensive damage, requiring costly repairs. Electrical protection for calibrator outputs is vital for daily operation. The 5080A calibrator’s innovative protection circuitry prevents it from being damaged by reversed input voltage, so you can use it with confidence day after day.

Highest voltage and current compliance

The 5080A has the highest voltage and current compliance of any calibrator in the Fluke Calibration multi-product and multifunction calibrator families, making it an ideal solution for calibrating analog meters and other instruments requiring higher drive capability for proper operation.

Maximum burden or compliance voltage
Functions
ModelDC voltageAC voltageDC currentAC current*
5080A600 mA800 mA50 V44 V
910020 mA20 mA4 V4 V
5500A10 mA10 mA4.5 V3 V
5520A10 mA10 mA7 V5 V
5700A50 mA50 mA10 V7 V
5720A50 mA50 mA10 V7 V

* With AC LCOMP on

Automate the 5080A Multi-Product Calibrator to increase efficiency and throughput

Versatile software applications enable automated calibration as well as paperless data collection and reporting

  • 5080/CAL. The 5080/CAL software is designed for calibrating analog and digital workload with the 5080A calibrator. It enables you to automate calibration, manage inventory, collect data and print reports, easily and economically.
  • MET/CAL® Lite for 5080A.MET/CAL Lite provides the power of MET/CAL Plus software in a lower cost version designed for use with 5080A calibrators.
  • MET/CAL® Plus. For the full spectrum of calibration automation and asset management, choose MET/CAL Plus software. Add Manual MET/CAL software for mechanical or dimensional workload where automation is not required.The solutions you need, from the leader in calibration

The solutions you need, from the leader in calibration

Fluke Calibration is a premium brand, well known around the world for its accurate, dependable, high quality products. Long known as a leader in dc and low frequency ac calibration, Fluke Calibration is also recognized for its offerings in temperature, pressure, power, process, and rf calibration. Fluke Calibration provides the calibrators, standards, software, service, support and training you need for a complete solution in your cal lab.

Technical Specifications
Voltage DC
 Range: 0 to ±1020V
 Best 1 Year Specification: ±0.01% of setting
Current DC
 Range: 0 to ±20.5A
 Best 1 Year Specification: ±0.05% of setting
Resistance
 Range: 0 to 190 MO, 19 values in x1 and x1.9
 Best 1 Year Specification: ±0.025% of setting
Voltage AC
 Range: 1 mV to 1020V
45Hz to 1 kHz, Sine
 Best 1 Year Specification: ±0.1% of setting
Current AC
 Range:29 mA to 20.5A
45 Hz to 1 kHz, Sine
 Best 1 Year Specification: ±0.1% of setting
DC Power
 Range:10.9 mW to 20.5 kW
 Best 1 Year Specification: ±0.11% of setting
AC Power
 Range: 10.9 mW to 20.5 kW
45-65 Hz, PF=1
 Best 1 Year Specification: ±0.36% of setting
Phase
 Range: 0 to ± 179.99°
45 Hz to 1 kHz
 Best 1 Year Specification: ±0.25° of setting
Frequency
 Range: 45 Hz to 1 kHz
 Best 1 Year Specification: ±50 ppm of setting

 

General Specifications
Warm up Time
 Twice the time since last warmed up, to a maximum of 30 minutes
Settling Time
 Less than 5 seconds for all functions and ranges except as noted
Standard Interfaces
 RS-232 and Ethernet
Temperature Performance
Operating: 0°C to 50°C
Calibration (tcal):15°C to 35°C
Storage:-20°C to +70°C
Temperature Coefficient
 Temperature coefficient for temperatures outside tcal ±5 °C is 10 % of the stated specification per °C for temperatures in the range of 0 °C to 35 °C. Above 35 °C, the temperature coefficient is 20 % of the stated specification per °C.
Relative Humidity
Operating: <80% to 30°C, <70% to 40°C, <40% to 50°C
Storage:<95%, non-condensing
Altitude
Operating: 2,000m (6,500 ft) maximum
Non-operating: 12,200m (40,000 ft) maximum
Safety
Meets EN. 61010-1:2001, CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1: 2004
Analog Low Isolation
20V
EMC
Meets EN613261:2006.
Line Power
Line Voltage (selectable): 100V, 120V, 220V, 240V
Line Frequency: 47 to 63 Hz
Line Voltage Variation: + 10% about line voltage setting
Power Consumption
600 VA
Calibration DocumentationReport of calibration with data included; 17025 accredited report optional
Dimensions
Height:19.3 cm (7.6 in)
Width:43.2 cm (17 in), 44.3 cm (17.5 in) including handles
Depth:53.8 cm (21.2 in)
Weight (without options)
22 kg (48 lbs.)
Absolute Uncertainty Definition
The specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. It is not necessary to add anything to determine the total specification for the temperature range indicated.
Specification Confidence Interval
99%


AccessoryDescription
9100-200

10/50 Turn Current Coil

5500A/COIL

50-Turn Current Coil

5080A Megohm Meter Calibration Option

5080A Megohm Meter Calibration Option

5080A/CASE

5080A/CASE

Silver CarePlan

Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Priority Gold Instrument CarePlan

Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email tocareplans@flukecal.com.